Since January 1, 2012, Medicare pays the technical component of advanced diagnostic imaging only to suppliers accredited by a CMS-designated organization. MRI, CT, nuclear medicine and PET are covered. X-ray, ultrasound, fluoroscopy and mammography are not.

← Back to Blog
4 min read · by White Glove Radiology
A medical physicist scanning a phantom on an MRI table during an annual performance evaluation.

Since January 1, 2012, Medicare pays the technical component of MRI, CT, nuclear medicine and PET only to suppliers accredited by a CMS-designated organization, under section 1834(e) and 42 CFR 414.68. X-ray, ultrasound, fluoroscopy and mammography are excluded. The interpretation itself is not accredited.

Enrolling in Medicare is not the only gate for an imaging center with advanced equipment. Section 1834(e) of the Social Security Act, in force since January 1, 2012, makes payment for the technical component of advanced diagnostic imaging services under the physician fee schedule depend on the supplier being accredited by a CMS-designated organization.

Which modalities need accreditation?

42 CFR 414.68(b) names four: magnetic resonance imaging, computed tomography, nuclear medicine and positron emission tomography. X-ray, ultrasound, fluoroscopy and mammography are excluded. Mammography has its own FDA certification under MQSA.

The requirement attaches to the supplier of the technical component, which means an IDTF and a physician office both need it for those services. The interpretation, the professional component, is not accredited. A radiologist who only reads studies does not need it, but the center that owns the scanner does.

Which criteria does an accreditor apply?

Section 1834(e)(3) sets criteria for each modality:

  • qualifications of nonphysician personnel;
  • qualifications of the medical director or supervising physician, including residency training, experience and continuing education;
  • equipment performance specifications;
  • safety of staff and patients;
  • a quality assurance and quality control program for image quality.

The regulation adds a procedure for beneficiary records access and a duty to notify the accreditor of changes in the modalities the supplier furnishes. An owner who adds a PET unit later cannot assume the existing accreditation covers it.

Who may accredit?

CMS designated three organizations in 2010: the American College of Radiology, the Intersocietal Accreditation Commission and The Joint Commission (75 FR 4088). A 2013 notice added a fourth, RadSite (78 FR 59701). CMS keeps the current list, so confirm it on CMS's site before choosing. Our post on choosing among them covers the comparison.

Where does the process begin?

Using the ACR as an example, the owner files an online application with personnel and equipment details, then submits a testing package with clinical images, scanning protocols, phantom images, dose measurements and quality control information. A medical physicist performs the annual system performance evaluation. ACR accreditation lasts three years from the date the first module passes, with random image checks and on-site validation surveys within the cycle. Each accreditor sets its own process and fees, so read the one you pick.

Does an accredited center have to maintain anything afterward?

Yes. Accreditation is a cycle, not a certificate on the wall. Using the ACR as the documented example, accreditation lasts three years from the date the first module or unit passes, and the program runs random image checks and on-site validation surveys within that period. A medical physicist performs the annual system performance evaluation and phantom dosimetry. Other accreditors set their own cycles, so ask each one for its schedule in writing.

The statute also expects ongoing quality assurance and quality control, which is a daily practice, not an annual one. A center that skips daily and weekly QC until the testing package is due is building its package from thin evidence.

What happens when a center adds or replaces a unit?

The regulation requires the supplier to notify the accreditor of a change in the modalities it furnishes. A center that adds PET to an accredited MRI and CT suite should expect that PET is not covered until the accreditor says so. A replacement unit raises a similar question: ask the accreditor whether it needs notice, an amended application or new testing before the unit is used for Medicare-billed studies.

The same event also touches the Medicare enrollment. A new modality means new codes and possibly a new equipment entry. See the equipment file and the CPT list.

Who needs to be involved in the application?

  • The owner or administrator, who signs and pays the accreditor's fee.
  • The medical director or supervising physician, whose qualifications the accreditor reviews.
  • The lead technologist, who assembles clinical images and protocols.
  • The medical physicist, who performs the system evaluation and phantom work.

Settling those roles before you apply is the quickest way to avoid a stalled package.

How does this relate to enrollment?

Accreditation and enrollment run side by side. A new center needs its IDTF enrollment and its accreditation before it can be paid for MRI, CT, nuclear medicine or PET technical services. Our Accreditation Readiness service prepares your application and testing package per site. The accreditor's fee is paid by the facility to the accreditor directly, and we do not accredit, certify or guarantee an outcome.

Common questions

Which imaging modalities require Medicare accreditation?
MRI, CT, nuclear medicine and PET. X-ray, ultrasound, fluoroscopy and mammography are excluded under 42 CFR 414.68(b).
Does a radiologist who only reads studies need accreditation?
No. Accreditation applies to the supplier of the technical component. The professional interpretation is not accredited.
Do I need to tell the accreditor when I add a modality?
Yes. The regulation requires notice to the accreditor of changes in the modalities a supplier furnishes.